<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15553</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: balance weight actuators extended
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Platesetter_VLF</Text></ListItem>
<ListItem><Text>Trendsetter_VLF</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Verify that the balance cylinder extended/retracted sensors are working
properly, and check the wiring/plumbing.
NOTE:  This error is obsolete in VLF trendsetter version 1.40 and newer.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
This is not an operator serviceable error.  Press resume or reset the
machine to continue production.  Call CreoScitex response center.
</text></DescriptionText>
</OperatorAction>
<Cause>
In order to move the drum safely, the two balance weight cylinders have
to be retracted.  This error message will appear if the firmware does
not see that both weight cylinders are retracted.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:12 2008 PST
</Updated>
<Links>
</Links>
</Error>